AM Ground System Information Collection Form

With some knowledge to the site in question, this form should take about 10-15 minutes to prepare and
submit. Depending on the current load of the 'net, the from should arrive in our mailbox anywhere from 5
seconds to 1 day after you press SUBMIT. If you have not received a call back from us within 24 hours,
your email may be floating around in the ether somewhere... Lost forever. PLEASE call our toll free
number if you have not received confirmation of receipt within 24 hours.
 

PLEASE NOTE:
Submitting this form implies absolutely NO obligation to you.
 
 

This form is meant to make both of our jobs easier and save time.  Please be as specific as
possible but if an answer isn't known we can work it out later.  If some
aspect of your project defies written word, or would take too long to write out, please
fill out what you can, submit the form and call to discuss the rest.  The answers provided on this form
will be used to compile a preliminary quote for this project.
 
 
 
 
Date
Your Name
Your Affiliation with Station
Call Sign of Station
Frequency mHz
Transmitter Location (City, State)
Your Telephone Number
Your Email Address
If Unlicensed, Latitude
Longitude
Consulting Engineer (if applicable)
Consultant Telephone Number
Desired Start Date of Ground System Construction
Desired Completion Date of Ground System Construction

 
Site Basics (Please Check All That Apply)
New Site Installation
Rebuild Existing Site
Plats or other engineering drawings available
Transmitter will be on while construction is underway
Tower(s) will be up while construction is underway
Conditions exist that will require job to be done at night or during restricted hours *** Please describe below ***
There be other work going on while ground system is being installed? (i.e., tower work, grading/excavating, road building, building construction, etc)
*** Please describe below ***
   
Description (if needed)

 
Site Use (Please Check All That Apply)
Unknown Previous Site Use
Pasture or Crop Land
Freshly Cleared Woods
Fresh Excavation to Hardpan
Fresh Excavation with Fill Dirt
Existing Tower Site
Other  *** Please describe below ***
Description (if needed)

 
Soil Type (Please Check All That Apply)
Unknown Soil Type
Sandy
Rocky
Clay
Gravel
Hard
Really Hard
Exposed Rock (as in rock ledges or boulders)
Soft
Muddy
Standing Water
Swamp
Good for a Parking Lot
Good for a Garden
Good for an Alligator Farm
Other (Please Describe Below)
   
Description (if needed)

 
 
Obstructions that may be present when ground system work begins
(Please Check All That Apply)
Unknown Site Obstructions
Tower
Building...   How far from tower base? ft
Buildings (Plural) *** Please provide drawing ***
Fences around tower
Other Fences in Ground Field Area
Drainage Ditches that can be crossed
Drainage Ditches that CAN'T be crossed
Ponds, streams or standing water
Roads that can be plowed across
Roads that CAN'T be plowed across
Parking Lot
Trees
Poles (Power, Telephone, etc)
Grave Yard
Non-mobile automobiles
Trash or other Rubbish
Excavation: Open trenches for power/Telco/etc
Excavation: Open trenches to towers for coax, etc
Excavation: Dirt Piles
Underground utilities less than 36in deep (Water, gas, power, telco, etc)
All other underground pipe/wiring/coax less than 36in deep
Will need assistance in determining underground obstructions
OTHER OBSTRUCTIONS *** Please describe below ***
   
Description (if needed)

 
 
Please check ONE to describe the site topography.
Unknown Site Topography
Level to sloping
Sloping to Rolling
Rolling to Sharply dropping away from tower
Rolling to Sharply rising away from tower
Hang on to your hat Steep
Other (Please Describe Below)
Description (if needed)

 
Site Security During Construction (Please Check All That Apply)
Unknown Site Security
Please rate site security concerns on a scale of 1 to 10. Where, 1 is a good neighborhood where you could leave everything unlocked without fear, and 10 where everything left onsite will be gone in the morning
Full site fence with locked gate
No full site fence but gated drive
No fence or gate on driveway
Other Security Concerns or Arrangements
Description (if needed)

 
Ground System Design (Please Check All That Apply)
Standard Ground System consists of 120 radials, 1/4 wavelength at lowest frequency
Unknown Ground System Design
Standard 120 Radial System
Standard 120 Radial System with Interspersed radials of length
Standard 120 Radial System with ground screen ft sq
Custom Designed Ground System with radials ft long and
ft of screen or interspersed radials
Contact Engineering Consultant for Design
Quote ground cover consisting of weed block fabric and gravel
Radials will be shortened in some directions due to property constraints or
obstructions *** Please provide drawing ***
Please design ground system based on included information.  Include info below
   
   
Description (if needed)

 
 
The following section is for Directional Arrays ONLY:
Unknown DA specifics
Will radials be shortened and bonded at intersection points?
OR overlapped?
If adding a tower and ONLY constructing new ground field for it, will it be necessary to locate ends of existing radials and bond them to new system?
   

 
 
If further information on any aspect of project is available or needed please provide it below

Thanks for taking the time to complete this questionnaire. We believe that a few
minutes spent in understanding each situation can save hours of work and lots of
headaches in the future.

Sincerely,
 

Kevin C. Kidd